翻訳と辞書
Words near each other
・ Thermal fluids
・ Thermal fracturing in glass
・ Thermal grease
・ Thermal grill illusion
・ Thermal Hall effect
・ Thermal Head
・ Thermal history coating
・ Thermal history modelling
・ Thermal history of the Earth
・ Thermal hydraulics
・ Thermal hydrolysis
・ Thermal imaging camera (firefighting)
・ Thermal immersion circulator
・ Thermal infrared spectroscopy
・ Thermal insulation
Thermal integrity profiling
・ Thermal ionization
・ Thermal ionization mass spectrometry
・ Thermal keratosis
・ Thermal lag
・ Thermal lance
・ Thermal laser stimulation
・ Thermal loop
・ Thermal low
・ Thermal management
・ Thermal management of electronic devices and systems
・ Thermal management of high-power LEDs
・ Thermal manikin
・ Thermal mass
・ Thermal mass flow meter


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Thermal integrity profiling : ウィキペディア英語版
Thermal integrity profiling

Thermal Integrity Profiling is a non-destructive testing method of evaluating the integrity of concrete foundations. It is standardized by (ASTM D7949 - Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations ).
The testing method was first developed at the University of South Florida.〔Mullins, G., Kranc, S., May 2007. Thermal Integrity Testing of Drilled Shafts. Final Report Submitted to Florida Department of Transportation, Project BD544-20: Tampa, FL.〕 It relates the heat generated by curing of cement to the integrity and quality of drilled shafts, augered cast in place (ACIP) piles and other concrete foundations. In general, a shortage of competent concrete (necks or inclusions) is registered by relative cool regions; the presence of extra concrete (over-pour bulging into soft soil strata) is registered by relative warm regions.
Cement temperatures are either sampled throughout the concrete hydration process 〔Piscsalko, G., Cotton, D., October 2011. Non-Destructive Testing Methods for Drilled Shaft and ACIP Piles. Proceedings from Deep Foundations Institute 36th Annual Conference on Deep Foundations: Boston, MA; 252-532.〕 or a test is conducted at a time prior to the peak curing temperature having been reached. Either way, measurements are available relatively soon after pouring (6 to 72 hours), typically earlier than when other integrity testing methods such as cross hole sonic logging and low strain integrity testing can be performed.
Temperatures are measured along the entire depth of the foundation. If records at a certain depth show regions with cooler temperatures (when compared to the average temperature at that depth), a concrete deficiency or defect may be present. An average temperature at a certain depth that is significantly lower than the average temperatures at other depths may also be indication of a potential problem. It is also possible to estimate the effective area of the foundation, and to assess if the reinforcing cage is properly aligned and centered.
〔Sellountou, A., Alvarez, C., Rausche, F., April 2013. Thermal Integrity Profiling: A Recent Technological Advancement in Integrity Evaluation of Concrete Piles. Proceedings from the First International Conference, Seminar on Deep Foundations: Santa Cruz , Bolivia.〕